DiacellĀ® PanoramicDAC
NRIXS, Mossbauer, Pmax = 100 GPa, T= 300 K, WD = 19 mm, 3 x 105Ā° azimuthal openings
- The DiacellĀ® PanoramicDAC is suitable for many applications such as Mossbauer, Raman, Brillouin spectroscopies, nuclear resonant inelastic X-ray scattering (NRIXS), nuclear forward scattering (NFS) techniques
- The cell enables measurements both via its three large azimuthal openings (through gasket) or the conventional axial conical apertures (through diamond anvils)
- The 3 side ports on the DiacellĀ® PanoramicDAC have openings of 105Ā° (azimuthal) by 67Ā° (axial)
- In the DiacellĀ® PanoramicDAC, high pressures are generated by Almax easyLab proprietary gas membrane, although it can also be operated manually via a set of clamping screws
- Maximum pressure of up to above 100 GPa may be obtained with the DiacellĀ® PanoramicDAC
Description
The DiacellĀ® PanoramicDAC is a diamond anvil cell suitable for many applications such as Mossbauer, Raman and Brillouin spectroscopies, nuclear resonant inelastic x-ray scattering (NRIXS), nuclear forward scattering (NFS) techniques amongst others.
This cell enables measurements both via its three large azimuthal openings (through gasket) or the conventional axial conical apertures (through diamond anvils).
The DAC body has three 105Ā° azimuthal openings allowing access to 315Ā° out of 360Ā° worth of radial diffraction. The azimuthal opening in horizontal direction is completed with 67Ā° radial vertical opening.
High pressures are generated by the original gas membrane driven design from DiacellĀ®.Ā However, this cell can also be operated manually via its clamping screws.
Specifications
Cell Material | Maraging Steel |
Anvil Support Plate | Tungsten Carbide |
Pressure Mechanism | Gas membrane or Screw Drive |
Maximum Pressure | Ā 100 GPa |
Temperature Range | 300 K |
Top Angle | Optical: conical 18Āŗ |
Bottom Angle | Optical: conical 62Ā° |
Azimuthal Ports | 3 ports:Ā 105Ā° (azimuthal) by 67Ā° (axial) |
Heating | N/A |
Cooling | N/A |
DAC Diameter | 59 mm |
DAC Height | 76 mm |
Working Distance to Sample | 19 mm |
Numerical Aperture | 0.50 |
Interfacing Solution | TBC |
DAC Weight | TBC |
Maximum pressure is dependent upon the culet size of the anvils. Almax easyLab is committed to its policy of continuous improvement. Specifications may change without notice. easyLab and Diacell are registered trademarks of Almax easyLab.
Documents
We have compiled a series of technical documents (brochures, articles, technical drawings, …) which you might find useful to help you understand this product better.
Technical documentation
Technical Drawing
Please contact us for further details on the engineering drawings.
FAQs
What is the maximum pressure I can achieve with the Panoramic DAC and a given culet size?
Culet size (Āµm) | 200 | 300 | 400 | 500 | 600 | 800 | 1000 |
Pmax (GPa) (*) | N/A | 98 | 63 | 41 | 28 | 16 | 10 |